A present reading is not every future test
Two preparations with the same path populations may still be distinguishable by recombination. For p=1/2, a state with φ=0 and a state with φ=90° both produce equal path probabilities. An X-basis comparison gives plus probabilities one and one half, respectively. A Y-basis comparison instead gives one half and one.
This is a concrete example of the future-test question in completion theory. A record that retains only the present path reading cannot predict every later phase-sensitive test. The relevant notion of completeness depends on the operations and measurements that are allowed afterward. [B05] [P02]
Our lab displays expected distributions for one preparation under three alternative apparatus settings. It does not perform incompatible measurements simultaneously on the same particle. Each distribution is estimated using a fresh ensemble prepared in the same way.
Switch the comparison basis
Set a relative phase and choose Path Z, Recombine X, or Shifted Y. The top pair of bars shows the selected test. The readout lists all three expectation values so that the missing information is explicit. Play changes the preparation phase; it does not change the selected apparatus basis.
Explore · Standard quantum baseline
Change the inputs and compare the numerical readout. Playback begins only when you press Play.
The interactive values require JavaScript. The diagram and worked equations provide the same mathematical construction.
Try φ=0 and φ=90° with equal path weights and full coherence. Z cannot distinguish them; X and Y can. Then set ν=0. The phase-sensitive components disappear while the population imbalance, if any, remains.
Reconstruct the two-path density matrix
The three real components form the Bloch vector. The Pauli matrices are a basis for traceless Hermitian two-by-two matrices; together with trace one, these three expectation values specify this density matrix. Positivity requires the vector to lie in the unit ball.
In the chosen convention, the Y-plus state is (|0⟩+i|1⟩)/√2. Stating this convention fixes the sign of the sine term. Changing a phase convention requires transforming the analyzer consistently.
The purity is tr(ρ²)=(1+|r|²)/2. For full coherence the preparation is pure; removing off-diagonal coherence generally reduces purity. If only one path is occupied, changing ν has no effect because there is no off-diagonal term to remove.
A record, a reduction, and an outcome
Discarding phase information, tracing out an environment, and selecting a particular measurement outcome are different operations. The density matrix used here predicts statistics. It does not independently choose a unique outcome or settle the interpretation of measurement. The book's discussion of records keeps those questions separate. [B11] [B24]
Similarly, reversible phase evolution does not by itself generate thermodynamic irreversibility. Memory and temporal asymmetry arise in specified reduced models with their own assumptions. The temporal-asymmetry paper and its guide are useful onward reading for that separate layer. [P04] [A04] [B12]
For this two-path baseline, three calibrated basis comparisons reconstruct the density operator. A larger physical system may need additional degrees of freedom, detector calibration, and tests. “Complete” always refers to a stated model and accessible family of comparisons.
Continue to composition to see why even a well-defined phase on each subsystem does not supply the composite rule automatically.

